3MGI
Ternary complex of a DNA polymerase lambda loop mutant
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU MICROMAX-007 HF |
| Temperature [K] | 277 |
| Detector technology | IMAGE PLATE |
| Detector | RIGAKU |
| Wavelength(s) | 1.504 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 56.177, 63.235, 140.382 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 25.114 - 2.603 |
| R-factor | 0.203 |
| Rwork | 0.200 |
| R-free | 0.27000 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.003 |
| RMSD bond angle | 0.796 |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | MOLREP |
| Refinement software | PHENIX |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 50.000 |
| High resolution limit [Å] | 2.600 |
| Number of reflections | 15905 |
| Completeness [%] | 99.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | hanging drop | 5.5 | 277 | 2-propanol, pH 5.5, hanging drop, temperature 277K |