Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3I77

35/99/170-loops of FXa in SGT

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 14-BM-C
Synchrotron siteAPS
Beamline14-BM-C
Temperature [K]100
Detector technologyCCD
Collection date2009-04-15
DetectorADSC QUANTUM 315
Wavelength(s)0.9000
Spacegroup nameI 4 2 2
Unit cell lengths138.351, 138.351, 81.402
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution35.080 - 2.100
R-factor0.16429
Rwork0.163
R-free0.19490
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1os8
RMSD bond length0.017
RMSD bond angle1.431
Data reduction softwareHKL-2000
Data scaling softwareSCALEPACK
Phasing softwareAMoRE
Refinement softwareREFMAC (5.5.0088)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]35.0802.150
High resolution limit [Å]2.1002.100
Rmerge0.1620.624
Number of reflections21801
<I/σ(I)>14.43.8
Completeness [%]98.9
Redundancy10.210.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP62981.5 M Ammonium sulfate, 10 mM Calcium acetate, pH 6.0, VAPOR DIFFUSION, HANGING DROP, temperature 298K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon