BHA10 IgG1 Fab double mutant variant - antibody directed at human LTBR

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 31-ID
Synchrotron siteAPS
Beamline31-ID
Temperature [K]100
Detector technologyCCD
Collection date2008-02-01
DetectorMAR CCD 165 mm
Wavelength(s)1.000
Spacegroup nameI 2 2 2
Unit cell lengths74.463, 127.608, 123.253
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution24.360 - 1.720
R-factor0.15964
Rwork0.158
R-free0.19033
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3hc0
RMSD bond length0.011
RMSD bond angle1.348
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareMOLREP
Refinement softwareREFMAC (5.2.0019)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.760
High resolution limit [Å]1.7201.720
Rmerge0.0760.483
Number of reflections62526
Completeness [%]99.594.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP829820% PEG 4000, 200 mM calcium acetate 10 mM zinc chloride and 100 mM Tris at pH 8, VAPOR DIFFUSION, SITTING DROP, temperature 298K