3GKI
NPC1(NTD):cholesterol
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 19-ID |
| Synchrotron site | APS |
| Beamline | 19-ID |
| Detector technology | CCD |
| Collection date | 2008-08-09 |
| Detector | ADSC QUANTUM 315 |
| Spacegroup name | P 64 |
| Unit cell lengths | 65.691, 65.691, 82.367 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 30.630 - 1.800 |
| R-factor | 0.1761 |
| Rwork | 0.174 |
| R-free | 0.20733 |
| Structure solution method | SAD |
| RMSD bond length | 0.012 |
| RMSD bond angle | 1.477 |
| Refinement software | REFMAC (5.3.0037) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 1.830 |
| High resolution limit [Å] | 1.800 | 1.800 |
| Rmerge | 0.059 | |
| Number of reflections | 18504 | |
| Completeness [%] | 98.8 | 94 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 4 | 294 | 25% PEG 1500, 100 mM MES Acid, 30 mM Glycine, pH 4.0, VAPOR DIFFUSION, HANGING DROP, temperature 294K |