Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3EEE

Probing the function of heme distortion in the H-NOX family

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 8.2.1
Synchrotron siteALS
Beamline8.2.1
Temperature [K]100
Detector technologyCCD
Collection date2005-08-28
DetectorADSC QUANTUM 315
Wavelength(s)1
Spacegroup nameC 1 2 1
Unit cell lengths116.253, 124.686, 83.555
Unit cell angles90.00, 126.58, 90.00
Refinement procedure
Resolution45.672 - 2.120
R-factor0.2071
Rwork0.205
R-free0.25190
Starting model (for MR)1u55
RMSD bond length0.008
RMSD bond angle0.898
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.240
High resolution limit [Å]2.1202.120
Rmerge0.0550.455
Number of reflections53717
<I/σ(I)>2.7
Redundancy4.33.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
19.12890.1 M NaSCN, 0.1 M Tris pH 9.1, 0.2 M (NH4)2(SO4), and 18% (w/v) PEG 8000 at 289K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon