Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

3BZG

UVDE pH4.4

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID14-2
Synchrotron siteESRF
BeamlineID14-2
Temperature [K]100
Detector technologyCCD
Collection date2007-07-16
DetectorMAR225
Wavelength(s)0.933
Spacegroup nameP 61 2 2
Unit cell lengths107.140, 107.140, 90.830
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution28.780 - 1.910
R-factor0.19823
Rwork0.196
R-free0.24437
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2j6v
RMSD bond length0.019
RMSD bond angle1.689
Data reduction softwareiMOSFLM
Data scaling softwareSCALA
Phasing softwareMOLREP
Refinement softwareREFMAC (5.2.0019)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]92.8482.010
High resolution limit [Å]1.9101.910
Rmerge0.0480.282
Number of reflections24142
<I/σ(I)>10.2
Completeness [%]99.2100
Redundancy6.46.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP4.4295Acetate, Naformate, MnCl2, pH4.4, VAPOR DIFFUSION, SITTING DROP, temperature 295K

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon