3BX8
Engineered Human Lipocalin 2 (LCN2), apo-form
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | BESSY BEAMLINE 14.1 |
| Synchrotron site | BESSY |
| Beamline | 14.1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2006-10-31 |
| Detector | MARMOSAIC 225 mm CCD |
| Wavelength(s) | 0.95373 |
| Spacegroup name | P 1 |
| Unit cell lengths | 61.482, 92.861, 98.825 |
| Unit cell angles | 110.77, 90.00, 109.36 |
Refinement procedure
| Resolution | 20.000 - 2.000 |
| Rwork | 0.251 |
| R-free | 0.28200 |
| Starting model (for MR) | 1DFV chain B |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | CNS |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 20.000 | 2.070 |
| High resolution limit [Å] | 2.000 | 2.000 |
| Number of reflections | 129807 | |
| <I/σ(I)> | 16.2 | 2 |
| Completeness [%] | 83.2 | 46.9 |
| Redundancy | 1.9 | 1.6 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |