3BX7
Engineered Human Lipocalin 2 (LCN2) in Complex with the Extracellular Domain of Human CTLA-4
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.1 |
Synchrotron site | BESSY |
Beamline | 14.1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2006-10-31 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 0.95373 |
Spacegroup name | P 32 2 1 |
Unit cell lengths | 120.706, 120.706, 82.957 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 20.000 - 2.100 |
Rwork | 0.209 |
R-free | 0.22600 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1I85 chain C PDB ENTRY 1DFV chain B |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | CNS |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 25.000 | 2.180 |
High resolution limit [Å] | 2.100 | 2.100 |
Number of reflections | 40987 | |
<I/σ(I)> | 30 | 3.3 |
Completeness [%] | 98.9 | 96.8 |
Redundancy | 8.6 | 8.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 8.4 | 293.15 | 1.4 M Na-malonate, pH 8.4, VAPOR DIFFUSION, SITTING DROP, temperature 293.15K |