36LC
RNA-L-G monomer complex
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 23-ID-B |
| Synchrotron site | APS |
| Beamline | 23-ID-B |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2025-06-27 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 1.0332 |
| Spacegroup name | P 3 2 1 |
| Unit cell lengths | 48.070, 48.070, 83.745 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 41.870 - 2.180 |
| R-factor | 0.2755 |
| Rwork | 0.272 |
| R-free | 0.30690 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.003 |
| RMSD bond angle | 1.025 |
| Data reduction software | autoPROC (1.0.5) |
| Data scaling software | autoPROC (1.0.5) |
| Phasing software | PHASER (2.8.3) |
| Refinement software | PHENIX (1.21.2_5419) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 41.870 | 2.520 |
| High resolution limit [Å] | 2.180 | 2.180 |
| Number of reflections | 3092 | 206 |
| <I/σ(I)> | 5.9 | |
| Completeness [%] | 88.2 | |
| Redundancy | 17.5 | |
| CC(1/2) | 0.930 | 0.730 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7 | 291 | 10% w/v Polyethylene glycol 6,000, 50 mM HEPES; pH 7.0, 200 mM Ammonium acetate, 150 mM Magnesium acetate |