2ZRM
MsRecA dATP form IV
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU RU200 |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2007-12-17 |
| Detector | MAR scanner 345 mm plate |
| Wavelength(s) | 1.54 |
| Spacegroup name | P 61 |
| Unit cell lengths | 101.899, 101.899, 75.490 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 29.420 - 2.800 |
| R-factor | 0.215 |
| Rwork | 0.215 |
| R-free | 0.26700 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1ubc |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.800 |
| Data reduction software | MOSFLM |
| Data scaling software | SCALA |
| Phasing software | AMoRE |
| Refinement software | CNS (1.2) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 30.000 | 2.950 |
| High resolution limit [Å] | 2.800 | 2.800 |
| Rmerge | 0.112 | 0.509 |
| Number of reflections | 11096 | |
| <I/σ(I)> | 16.9 | 3.9 |
| Completeness [%] | 100.0 | 100 |
| Redundancy | 7.2 | 7.1 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.9 | 296 | 80mM citrate/phosphate buffer(pH 6.9), 80mM NaCl, 40mM ammonium acetate, 20mM sodium citrate, 6% poly-ethylene glycol 3350, 30% poly-ethylene glycol 3350, 200mM ammonium acetate in sodium citrate buffer(PH 5.8), VAPOR DIFFUSION, HANGING DROP, temperature 296K |