2ZR9
MsRecA Q196E dATP form IV
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU RU200 |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2007-06-17 |
| Detector | MAR scanner 345 mm plate |
| Wavelength(s) | 1.54 |
| Spacegroup name | P 61 |
| Unit cell lengths | 101.959, 101.959, 75.150 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 29.430 - 2.500 |
| R-factor | 0.21 |
| Rwork | 0.210 |
| R-free | 0.25100 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1ubc |
| RMSD bond length | 0.007 |
| RMSD bond angle | 2.200 |
| Data reduction software | MOSFLM |
| Data scaling software | SCALA |
| Phasing software | AMoRE |
| Refinement software | CNS (1.2) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 30.000 | 2.640 |
| High resolution limit [Å] | 2.500 | 2.500 |
| Rmerge | 0.082 | 0.464 |
| Number of reflections | 15503 | |
| <I/σ(I)> | 16.8 | 3 |
| Completeness [%] | 99.9 | 100 |
| Redundancy | 5.4 | 4.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.9 | 296 | 80mM citrate/phosphate buffer(pH 6.9), 80mM NaCl, 40mM ammonium acetate, 20mM sodium citrate, 6% poly-ethylene glycol 3350, 30% poly-ethylene glycol 3350, 200mM ammonium acetate in sodium citrate buffer(PH 5.8), VAPOR DIFFUSION, HANGING DROP, temperature 296K |