2YNS
rImp_alpha_B54NLS
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | CCD |
Detector | ADSC QUANTUM 315r |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 62.242, 141.405, 73.325 |
Unit cell angles | 90.00, 90.17, 90.00 |
Refinement procedure
Resolution | 19.908 - 2.100 |
R-factor | 0.1748 |
Rwork | 0.177 |
R-free | 0.19740 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4b8p |
RMSD bond length | 0.014 |
RMSD bond angle | 1.681 |
Data reduction software | XDS |
Data scaling software | SCALA |
Phasing software | MOLREP |
Refinement software | PHENIX ((PHENIX.REFINE)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 19.950 | 2.210 |
High resolution limit [Å] | 2.100 | 2.100 |
Rmerge | 0.110 | 0.910 |
Number of reflections | 73652 | |
<I/σ(I)> | 10.8 | 2.1 |
Completeness [%] | 99.8 | 99.9 |
Redundancy | 6.1 | 5.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 0.1 M BIS-TRISPROPANE PH 7.0, 15-17% PEG 3350 AND 0.2 M NAF |