2YKF
Sensor region of a sensor histidine kinase
Experimental procedure
Experimental method | MAD |
Source type | SYNCHROTRON |
Source details | EMBL/DESY, HAMBURG BEAMLINE X12 |
Synchrotron site | EMBL/DESY, HAMBURG |
Beamline | X12 |
Temperature [K] | 100 |
Detector technology | CCD |
Detector | MARRESEARCH |
Wavelength(s) | 0.9190, 0.9187, 0.9050 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 73.590, 81.270, 105.060 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.500 - 2.000 |
R-factor | 0.19021 |
Rwork | 0.188 |
R-free | 0.23956 |
Structure solution method | OTHER |
Starting model (for MR) | NONE |
RMSD bond length | 0.023 |
RMSD bond angle | 1.927 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | Auto-Rickshaw |
Refinement software | REFMAC (5.5.0072) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 19.500 | |
High resolution limit [Å] | 2.000 | 2.000 |
Rmerge | 0.080 | 0.550 |
Number of reflections | 21659 | |
<I/σ(I)> | 16.5 | 3.5 |
Completeness [%] | 99.8 | 99.4 |
Redundancy | 3.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 7.5 | pH 7.5 | ||
1 | 7.5 | pH 7.5 |