Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

2XQ8

Pentameric ligand gated ion channel GLIC in complex with zinc ion (Zn2+)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06SA
Synchrotron siteSLS
BeamlineX06SA
Temperature [K]90
Detector technologyPIXEL
Collection date2009-05-10
DetectorDECTRIS PILATUS 6M
Spacegroup nameC 1 2 1
Unit cell lengths183.314, 128.310, 164.374
Unit cell angles90.00, 104.04, 90.00
Refinement procedure
Resolution40.200 - 3.600
R-factor0.2385
Rwork0.238
R-free0.24850
Structure solution methodOTHER
Starting model (for MR)NONE
RMSD bond length0.011
RMSD bond angle1.457
Data reduction softwareXDS
Data scaling softwareXDS
Refinement softwarePHENIX ((PHENIX.REFINE))
Data quality characteristics
 Overall
Low resolution limit [Å]39.720
High resolution limit [Å]3.600
Rmerge0.130
Number of reflections54863
<I/σ(I)>15.5
Completeness [%]99.0
Redundancy6.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP42779% PEG4000, 50MM CH3COONA, 200MM (NH4)2SO4, PH4.0, VAPOR DIFFUSION, HANGING DROP, TEMPERATURE 277.15K, VAPOR DIFFUSION, HANGING DROP

218853

PDB entries from 2024-04-24

PDB statisticsPDBj update infoContact PDBjnumon