2XQ7
Pentameric ligand gated ion channel GLIC in complex with cadmium ion (Cd2+)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 90 |
Detector technology | PIXEL |
Collection date | 2010-04-12 |
Detector | DECTRIS PILATUS 6M |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 183.314, 128.310, 164.374 |
Unit cell angles | 90.00, 104.04, 90.00 |
Refinement procedure
Resolution | 40.200 - 3.400 |
R-factor | 0.2432 |
Rwork | 0.242 |
R-free | 0.26550 |
Structure solution method | OTHER |
Starting model (for MR) | NONE |
RMSD bond length | 0.010 |
RMSD bond angle | 1.331 |
Data reduction software | XDS |
Data scaling software | XDS |
Refinement software | PHENIX ((PHENIX.REFINE)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 50.000 |
High resolution limit [Å] | 3.400 |
Rmerge | 0.100 |
Number of reflections | 50052 |
<I/σ(I)> | 9.8 |
Completeness [%] | 87.1 |
Redundancy | 3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 4 | 277.15 | 9% PEG 4000, 50MM CH3COONA, 200MM (NH4)2SO4, PH 4.0, VAPOR DIFFUSION, HANGING DROP, TEMPERATURE 277.15K, VAPOR DIFFUSION, HANGING DROP. |