2XK0
Solution structure of the Tudor domain from Drosophila Polycomblike (Pcl)
Spectrometer
Experimental method: SOLUTION NMR
Spectrometer ID | Spectrometer maker | Spectrometer model | Spectrometer type | Spectrometer field strength |
1 | Bruker | DMX | 500 | |
2 | Bruker | 600 | ||
3 | Bruker | 750 | ||
4 | Bruker | 900 |
Experiment
experiment id | conditions id | solution id | Experiment type |
1 | 1 | 1 | HNCA |
10 | 1 | 1 | CD |
11 | 1 | 1 | CE)HE |
12 | 1 | 1 | 1H-15N HSQC- NOESY |
13 | 1 | 1 | 1H-13C HMQC-NOESY |
2 | 1 | 1 | HNCACB |
3 | 1 | 1 | CBCA(CO)NH |
4 | 1 | 1 | (H)CC(CO)NH-TOCSY |
5 | 1 | 1 | H(CC)(CO) NH-TOCSY |
6 | 1 | 1 | H(C)CH-TOCSY |
7 | 1 | 1 | (HB)CB(CG |
8 | 1 | 1 | CD)HD |
9 | 1 | 1 | (HB)CB(CG |
NMR Sample
conditions id | NMR sample pH | NMR sample pressure | NMR sample temperature |
1 | 6.3 | 1.0 | 298.5 |
Conformers
Conformers Calculated Total Number | 100 |
Conformers Submitted Total Number | 10 |