2XGR
extracellular endonuclease
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE BM14 |
Synchrotron site | ESRF |
Beamline | BM14 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2008-01-30 |
Detector | MARMOSAIC 225 mm CCD |
Spacegroup name | P 32 2 1 |
Unit cell lengths | 76.420, 76.420, 80.434 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 38.210 - 1.700 |
R-factor | 0.1647 |
Rwork | 0.163 |
R-free | 0.20370 |
Structure solution method | SIRAS |
Starting model (for MR) | NONE |
RMSD bond length | 0.022 |
RMSD bond angle | 1.901 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | autoSHARP |
Refinement software | REFMAC (5.5.0109) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 51.100 | 1.790 |
High resolution limit [Å] | 1.700 | 1.700 |
Rmerge | 0.090 | 0.460 |
Number of reflections | 30345 | |
<I/σ(I)> | 19.8 | 5.3 |
Completeness [%] | 100.0 | 100 |
Redundancy | 10.7 | 10.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 6 | MALIC/MES/TRIS SYSTEM PH 6.0 25% PEG 1.5K. |