2WOH
Strontium soaked E. coli copper amine oxidase
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU RU200 |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Detector | RIGAKU IMAGE PLATE |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 135.135, 166.911, 79.796 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 37.820 - 2.700 |
| R-factor | 0.18847 |
| Rwork | 0.186 |
| R-free | 0.24280 |
| Structure solution method | OTHER |
| Starting model (for MR) | NONE |
| RMSD bond length | 0.004 |
| RMSD bond angle | 0.853 |
| Data reduction software | MOSFLM |
| Data scaling software | SCALA |
| Refinement software | REFMAC (5.5.0066) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 39.600 | 2.850 |
| High resolution limit [Å] | 2.700 | 2.700 |
| Rmerge | 0.070 | 0.300 |
| Number of reflections | 49169 | |
| <I/σ(I)> | 14.3 | 3.6 |
| Completeness [%] | 98.1 | 99.5 |
| Redundancy | 3.1 | 3 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 |