2WEG
Thermodynamic Optimisation of Carbonic Anhydrase Fragment Inhibitors
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID23-1 |
Synchrotron site | ESRF |
Beamline | ID23-1 |
Temperature [K] | 100 |
Detector technology | CCD |
Detector | ADSC CCD |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 42.432, 41.223, 72.038 |
Unit cell angles | 90.00, 104.26, 90.00 |
Refinement procedure
Resolution | 26.640 - 1.100 |
R-factor | 0.166 |
Rwork | 0.165 |
R-free | 0.18300 |
Structure solution method | OTHER |
Starting model (for MR) | NONE |
RMSD bond length | 0.034 |
RMSD bond angle | 2.614 |
Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 41.000 |
High resolution limit [Å] | 1.100 |
Rmerge | 0.070 |
Number of reflections | 308902 |
<I/σ(I)> | 10 |
Completeness [%] | 95.0 |
Redundancy | 3.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |