2WDU

Fasciola hepatica sigma class GST

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsSIEMENS ROTATING ANODE COPPER K ALPHA
Temperature [K]100
Detector technologyIMAGE PLATE
DetectorMARRESEARCH
Spacegroup nameP 21 21 21
Unit cell lengths53.947, 87.419, 93.988
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution64.420 - 1.620
R-factor0.19262
Rwork0.191
R-free0.22384
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2w9b
RMSD bond length0.014
RMSD bond angle1.428
Data reduction softwareMOSFLM
Data scaling softwareSCALA
Phasing softwareMOLREP
Refinement softwareREFMAC (5.0)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0001.700
High resolution limit [Å]1.6101.610
Rmerge0.0700.590
Number of reflections56342
<I/σ(I)>16.11.7
Completeness [%]95.577.9
Redundancy4.64
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
10.15M KBR, 20% PEG 3350

219140