2WCB

S100A12 complex with zinc in the absence of calcium

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE BM14
Synchrotron siteESRF
BeamlineBM14
Temperature [K]120
Detector technologyCCD
DetectorMARMOSAIC 225 mm CCD
Spacegroup nameF 2 2 2
Unit cell lengths83.696, 83.743, 155.540
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution77.850 - 1.730
R-factor0.228
Rwork0.226
R-free0.26100
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1e8a
RMSD bond length0.021
RMSD bond angle1.830
Data reduction softwareHKL-2000
Data scaling softwareSCALEPACK
Phasing softwareMOLREP
Refinement softwareREFMAC (5.5.0082)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]77.800
High resolution limit [Å]1.7301.730
Rmerge0.0800.720
Number of reflections28275
<I/σ(I)>17.11.7
Completeness [%]99.699.6
Redundancy5.13.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
17.534% PEG 3350, MME, 0.2M TRI AMMONIUM CITRATE PH 7.0

222624