2W5H
Human Nek2 kinase Apo
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I03 |
Synchrotron site | Diamond |
Beamline | I03 |
Temperature [K] | 100 |
Detector technology | CCD |
Detector | ADSC CCD |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 99.739, 56.962, 80.612 |
Unit cell angles | 90.00, 133.36, 90.00 |
Refinement procedure
Resolution | 58.610 - 2.330 |
R-factor | 0.197 |
Rwork | 0.195 |
R-free | 0.25400 |
Structure solution method | OTHER |
RMSD bond length | 0.006 |
RMSD bond angle | 0.964 |
Refinement software | PHENIX ((PHENIX.REFINE)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 58.600 |
High resolution limit [Å] | 2.330 |
Rmerge | 0.110 |
Number of reflections | 12969 |
<I/σ(I)> | 6.1 |
Completeness [%] | 91.3 |
Redundancy | 3.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 50 MM TRIS, PH 8.5 2-10% PEG8000 |