Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID14-3 |
Synchrotron site | ESRF |
Beamline | ID14-3 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2000-06-10 |
Detector | ADSC CCD |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 73.705, 171.164, 85.050 |
Unit cell angles | 90.00, 91.61, 90.00 |
Refinement procedure
Resolution | 20.000 - 2.870 |
R-factor | 0.258 |
Rwork | 0.257 |
R-free | 0.31100 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2vgb |
RMSD bond length | 0.023 |
RMSD bond angle | 2.162 |
Data reduction software | MOSFLM |
Data scaling software | CCP4 |
Phasing software | CCP4 |
Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 3.000 |
High resolution limit [Å] | 2.900 | 2.900 |
Rmerge | 0.100 | 0.280 |
Number of reflections | 42512 | |
<I/σ(I)> | 7.2 | 2.4 |
Completeness [%] | 89.0 | 68.6 |
Redundancy | 1.8 | 1.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | 6.4 | pH 6.4 |