Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

2VB1

HEWL at 0.65 angstrom resolution

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 19-ID
Synchrotron siteAPS
Beamline19-ID
Temperature [K]100
Detector technologyCCD
Collection date2006-07-05
DetectorADSC CCD
Spacegroup nameP 1
Unit cell lengths27.070, 31.250, 33.760
Unit cell angles87.98, 108.00, 112.11
Refinement procedure
Resolution30.000 - 0.650
R-factor0.0848
R-free0.09520
Structure solution methodOTHER
Starting model (for MR)NONE
RMSD bond length0.024
RMSD bond angle0.060
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareACORN
Refinement softwareSHELXL-97
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]30.0000.670
High resolution limit [Å]0.6500.650
Rmerge0.0400.180
Number of reflections187165
<I/σ(I)>36.24.2
Completeness [%]97.667.3
Redundancy7.12.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP4.7SITTING DROP METHOD. PROTEIN SOLUTION: 35 MG/ML HEWL, 0.02 M NA ACETATE BUFFER PH 4.7 WELL SOLUTION: 1 M NANO3, 0.1 M NA ACETATE BUFFER PH 4.7, 20 % ETHYLENE GLYCOL PROTEIN AND WELL SOLUTIONS MIXED 1:1 IN A DROP AND SEEDED

225158

PDB entries from 2024-09-18

PDB statisticsPDBj update infoContact PDBjnumon