2VAS

Myosin VI (MD-insert2-CaM, Delta-Insert1) Post-rigor state

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID23-2
Synchrotron siteESRF
BeamlineID23-2
Temperature [K]100
Detector technologyCCD
Collection date2006-06-29
DetectorADSC CCD
Spacegroup nameP 21 21 21
Unit cell lengths73.420, 100.470, 174.070
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution48.280 - 2.400
R-factor0.219
Rwork0.217
R-free0.25600
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2bkh
RMSD bond length0.009
RMSD bond angle1.222
Data reduction softwareXDS
Data scaling softwareSCALA
Phasing softwarePHASER
Refinement softwareREFMAC (5.2.0019)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.9702.530
High resolution limit [Å]2.4002.400
Rmerge0.1000.380
Number of reflections51218
<I/σ(I)>17.26.6
Completeness [%]100.0100
Redundancy8.28.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
18% PEG 8000, 50MM GLYCINE PH 9.5, 6% MPD

243531