Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU200 |
Temperature [K] | 287 |
Detector technology | AREA DETECTOR |
Detector | SIEMENS |
Spacegroup name | P 64 2 2 |
Unit cell lengths | 144.900, 144.900, 109.400 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 90.000 - 2.600 |
Rwork | 0.208 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2ltn |
RMSD bond length | 0.016 |
RMSD bond angle | 20.370 * |
Data reduction software | X-GEN |
Data scaling software | X-GEN |
Phasing software | X-PLOR |
Refinement software | TNT (5E) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 90.000 |
High resolution limit [Å] | 2.400 |
Rmerge | 0.126 |
Number of reflections | 17287 |
Completeness [%] | 81.0 |
Redundancy | 3.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | Vapor diffusion * | 7.2 | 4 * | 0.1 M HEPES, PH 7.2; 1 MM CACL2; 1 MM MNCL2 0.5 M NACL |
Crystallization Reagents
ID | crystal ID | solution ID | reagent name | concentration | details |
1 | 1 | 2 | 0.1 M HEPES, PH 7.2 | ||
2 | 1 | 2 | 1 MM CACL2 | ||
3 | 1 | 2 | 1 MM MMCL2 | ||
4 | 1 | 2 | 0.5 M NACL |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | drop | SBA | 34 (mg/ml) | |
2 | 1 | drop | sugar | 0.755 (M) | |
3 | 1 | drop | HEPES | 0.1 (M) | |
4 | 1 | drop | 1 (mM) | ||
5 | 1 | drop | 1 (mM) | ||
6 | 1 | drop | 0.15 (M) | ||
7 | 1 | reservoir | HEPES | 0.1 (M) | |
8 | 1 | reservoir | 0.5 (M) |