2QK0
Structural Basis of Microtubule Plus End Tracking by XMAP215, CLIP-170 and EB1
Experimental procedure
| Experimental method | MAD |
| Source type | SYNCHROTRON |
| Source details | ALS BEAMLINE 8.2.2 |
| Synchrotron site | ALS |
| Beamline | 8.2.2 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2002-07-23 |
| Detector | ADSC QUANTUM 315 |
| Wavelength(s) | 0.97964, 1.12713 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 27.242, 42.533, 51.806 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 32.880 - 2.000 |
| Rwork | 0.173 |
| R-free | 0.23300 |
| Structure solution method | MAD |
| Data reduction software | DENZO |
| Data scaling software | SCALEPACK |
| Phasing software | CNS |
| Refinement software | CNS |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.070 |
| High resolution limit [Å] | 2.000 | 2.000 |
| Rmerge | 0.046 | 0.079 |
| Number of reflections | 7855 | |
| <I/σ(I)> | 37.6 | 15 |
| Completeness [%] | 99.4 | 99.9 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 9 | 293 | 1.2 M Sodium malonate, 100 mM Glycine, 1.1 mM Lanthanum chloride, Protein concentration 15 mg/ml, pH 9.0, VAPOR DIFFUSION, HANGING DROP, temperature 293K |
| 1 | VAPOR DIFFUSION, HANGING DROP | 9 | 293 | 1.2 M Sodium malonate, 100 mM Glycine, 1.1 mM Lanthanum chloride, Protein concentration 15 mg/ml, pH 9.0, VAPOR DIFFUSION, HANGING DROP, temperature 293K |