2Q8R
Structural and Functional Characterization of CC Chemokine CCL14
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 8.2.1 |
Synchrotron site | ALS |
Beamline | 8.2.1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2003-09-07 |
Detector | ADSC QUANTUM 210 |
Wavelength(s) | 1.000 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 56.139, 57.553, 85.442 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 47.670 - 1.820 |
R-factor | 0.176 |
Rwork | 0.174 |
R-free | 0.22800 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2q8t |
RMSD bond length | 0.013 |
RMSD bond angle | 1.243 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | PHASER |
Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.890 |
High resolution limit [Å] | 1.820 | 1.820 |
Rmerge | 0.054 | 0.170 |
Number of reflections | 25453 | |
<I/σ(I)> | 35.32 | 11.2 |
Completeness [%] | 99.6 | 96.3 |
Redundancy | 8 | 7.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 298 | 0.2M magnesium acetate, 0.1M sodium cacodylate pH 6.5, 20% PEG 8000, VAPOR DIFFUSION, HANGING DROP, temperature 298.0K |