2PKL
Androgen receptor LBD with small molecule
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ALS BEAMLINE 8.3.1 |
| Synchrotron site | ALS |
| Beamline | 8.3.1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2006-08-31 |
| Detector | ADSC QUANTUM 210 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 55.070, 66.430, 72.760 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 25.000 - 2.490 |
| R-factor | 0.23 |
| R-free | 0.26000 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Data reduction software | ELVES |
| Data scaling software | ELVES |
| Phasing software | CNS |
| Refinement software | ELVES |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 25.000 | |
| High resolution limit [Å] | 2.490 | 2.490 |
| Rmerge | 0.114 | 0.114 |
| Number of reflections | 9122 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 298 | VAPOR DIFFUSION, SITTING DROP, temperature 298K |