Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

2PIU

Androgen receptor LBD with small molecule

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 8.3.1
Synchrotron siteALS
Beamline8.3.1
Temperature [K]100
Detector technologyCCD
Collection date2005-07-17
DetectorADSC QUANTUM 210
Spacegroup nameP 21 21 21
Unit cell lengths56.180, 66.070, 72.750
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution25.000 - 2.120
Rwork0.240
R-free0.27000
Structure solution methodMOLECULAR REPLACEMENT
Data reduction softwareELVES
Data scaling softwareELVES
Phasing softwareCNS
Refinement softwareELVES
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]25.000
High resolution limit [Å]2.1202.120
Rmerge0.1060.106
Number of reflections15599
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP298VAPOR DIFFUSION, SITTING DROP, temperature 298K

226707

PDB entries from 2024-10-30

PDB statisticsPDBj update infoContact PDBjnumon