Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

2PBX

Vibrio cholerae HapR

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSLS BEAMLINE X6A
Synchrotron siteNSLS
BeamlineX6A
Temperature [K]100
Detector technologyCCD
Collection date2005-03-17
DetectorADSC
Wavelength(s)1.0093
Spacegroup nameP 21 21 21
Unit cell lengths43.785, 85.085, 110.385
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution19.470 - 2.200
R-factor0.23298
Rwork0.230
R-free0.26260
Structure solution methodRIPAS
RMSD bond length0.041
RMSD bond angle3.189
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareSOLVE
Refinement softwareREFMAC (5.2.0005)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]67.2002.300
High resolution limit [Å]2.2002.200
Rmerge0.0590.206
Number of reflections21439
<I/σ(I)>17.685.69
Completeness [%]98.399.1
Redundancy55
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP0.2 M HEPES pH 7.5, 12% (wt/vol) polyethylene glycol 8000, and 5% (vol/vol) ethylene glycol, VAPOR DIFFUSION, HANGING DROP
1VAPOR DIFFUSION, HANGING DROP0.2 M HEPES pH 7.5, 12% (wt/vol) polyethylene glycol 8000, and 5% (vol/vol) ethylene glycol, VAPOR DIFFUSION, HANGING DROP

224572

PDB entries from 2024-09-04

PDB statisticsPDBj update infoContact PDBjnumon