Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

2OS7

Caf1M periplasmic chaperone tetramer

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID14-2
Synchrotron siteESRF
BeamlineID14-2
Temperature [K]100
Detector technologyCCD
Collection date2004-01-01
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.933
Spacegroup nameP 21 21 2
Unit cell lengths141.092, 174.267, 60.580
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution30.000 - 2.900
R-factor0.25157
Rwork0.249
R-free0.29843
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)Caf1M (chain A) from pdb entry 1p5v
RMSD bond length0.017
RMSD bond angle1.654
Data reduction softwareMOSFLM
Data scaling softwareCCP4 ((SCALA))
Phasing softwareMOLREP
Refinement softwareREFMAC (5.2.0005)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]200.0003.160
High resolution limit [Å]2.9002.900
Rmerge0.1650.400
Number of reflections33968
<I/σ(I)>3.83.8
Completeness [%]99.999.9
Redundancy66
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP82938% PEG 6000 in 50 mM Tris-HCl pH 8.0-8.3, VAPOR DIFFUSION, HANGING DROP, temperature 293K

218853

PDB entries from 2024-04-24

PDB statisticsPDBj update infoContact PDBjnumon