2O5S
Cobalt horse heart myoglobin, nitrite modified
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU300 |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2006-05-10 |
Detector | RIGAKU RAXIS IV |
Wavelength(s) | 1.54178 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 35.168, 28.680, 63.356 |
Unit cell angles | 90.00, 106.09, 90.00 |
Refinement procedure
Resolution | 26.580 - 1.600 |
R-factor | 0.17624 |
Rwork | 0.174 |
R-free | 0.21524 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.012 |
RMSD bond angle | 2.280 |
Data reduction software | d*TREK |
Data scaling software | d*TREK |
Phasing software | MOLREP |
Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 26.580 |
High resolution limit [Å] | 1.600 |
Rmerge | 0.044 |
Number of reflections | 15758 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.4 | 296 | Ammonium sulfate, pH 7.4, VAPOR DIFFUSION, HANGING DROP, temperature 296K |