Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

2O5Q

Manganese horse heart myoglobin, nitric oxide modified

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RU300
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2005-12-01
DetectorRIGAKU RAXIS IV
Wavelength(s)1.54178
Spacegroup nameP 1 21 1
Unit cell lengths35.468, 28.637, 63.193
Unit cell angles90.00, 105.70, 90.00
Refinement procedure
Resolution26.570 - 1.900
R-factor0.18029
Rwork0.177
R-free0.23543
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.022
RMSD bond angle2.672
Data reduction softwared*TREK
Data scaling softwared*TREK
Phasing softwareMOLREP
Refinement softwareREFMAC (5.2.0019)
Data quality characteristics
 Overall
Low resolution limit [Å]34.140
High resolution limit [Å]1.900
Rmerge0.095
Number of reflections9669
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.4296Ammonium sulfate, pH 7.4, VAPOR DIFFUSION, HANGING DROP, temperature 296K

218853

PDB entries from 2024-04-24