2NQN
MoeA T100W
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NSLS BEAMLINE X26C |
Synchrotron site | NSLS |
Beamline | X26C |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2001-04-16 |
Detector | ADSC QUANTUM 4 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 69.079, 98.659, 158.997 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 49.390 - 2.200 |
R-factor | 0.228 |
Rwork | 0.225 |
R-free | 0.27400 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 1.493 |
Refinement software | REFMAC (5.1.24) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 50.000 |
High resolution limit [Å] | 2.200 |
Number of reflections | 51582 |
Completeness [%] | 100.0 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 298 | 10%-15% PEG 6000/8000, 0.2-0.5 M calcium acetate, 0.1 M cacodylic acid, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 298K |