2NLB
Human beta-defensin-1 (Mutant Asn4Ala)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RU200 |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2005-08-14 |
Detector | MAR scanner 345 mm plate |
Wavelength(s) | 1.54178 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 46.520, 26.400, 57.530 |
Unit cell angles | 90.00, 100.80, 90.00 |
Refinement procedure
Resolution | 30.000 - 1.850 |
R-factor | 0.182 |
Rwork | 0.179 |
R-free | 0.23800 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1ijv |
RMSD bond length | 0.016 |
RMSD bond angle | 1.523 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | AMoRE |
Refinement software | REFMAC |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 40.000 | 1.920 |
High resolution limit [Å] | 1.850 | 1.850 |
Rmerge | 0.080 | 0.255 |
Number of reflections | 12053 | |
<I/σ(I)> | 17.1 | 6 |
Completeness [%] | 99.9 | 99.6 |
Redundancy | 5.2 | 5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 6.5 | 293 | PEG 8000, AMMONIUM SULFATE, SODIUM CACODYLATE, pH 6.5, vapor diffusion, temperature 293K |