Experimental procedure
| Detector technology | AREA DETECTOR |
| Collection date | 1991 |
| Detector | SIEMENS |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 98.400, 124.200, 274.900 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 30.000 - 2.800 |
| Rwork | 0.223 |
| RMSD bond length | 0.018 * |
| RMSD bond angle | 2.500 * |
| Data reduction software | XDS |
| Data scaling software | CCP4 |
| Refinement software | TNT |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 4.500 * |
| High resolution limit [Å] | 2.800 * |
| Rmerge | 0.092 * |
| Total number of observations | 178986 * |
| Number of reflections | 36781 * |
| Redundancy | 3.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | Batch method * | 6.7 * | macroseeding * |
Crystallization Reagents in Literatures
| ID | crystal ID | solution | reagent name | concentration (unit) | details |
| 1 | 1 | 1 | ammonium salfate | 1.35 (M) | |
| 2 | 1 | 1 | potassium chloride | 500 (mM) | |
| 3 | 1 | 1 | potassium phosphate | 50 (mM) | |
| 4 | 1 | 2 | dithiothreitol | 5 (mM) | |
| 5 | 1 | 2 | 0.5 (mM) | ||
| 6 | 1 | 2 | prtein | 8-12 (mg/ml) |