2MBV
LMO4-LIM2 in complex with DEAF1 (404-418)
Spectrometer
Experimental method: SOLUTION NMR
Spectrometer ID | Spectrometer maker | Spectrometer model | Spectrometer type | Spectrometer field strength |
1 | Bruker | AVANCE | Bruker Avance | 600 |
2 | Bruker | AVANCE | Bruker Avance | 800 |
Experiment
experiment id | conditions id | solution id | Experiment type |
1 | 1 | 1 | 2D 1H-15N HSQC |
10 | 1 | 1 | 3D HNCO |
11 | 1 | 1 | 3D HNCACO |
12 | 1 | 1 | 3D 1H-15N NOESY |
13 | 1 | 1 | 3D 1H-13C NOESY aliphatic |
2 | 1 | 1 | 2D 1H-13C HSQC |
3 | 1 | 1 | 2D DQF-COSY |
4 | 1 | 1 | 2D 1H-1H TOCSY |
5 | 1 | 1 | 2D 1H-1H NOESY |
6 | 1 | 1 | 3D CBCA(CO)NH |
7 | 1 | 1 | 3D HNCACB |
8 | 1 | 1 | 3D H(CCO)NH |
9 | 1 | 1 | 3D HCCH-TOCSY |
NMR Sample
conditions id | NMR sample pH | NMR sample pressure | NMR sample temperature |
1 | 5 | ambient | 298 |
Conformers
Conformers Calculated Total Number | 50 |
Conformers Submitted Total Number | 20 |