2J64
H-ficolin
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID14-3 |
Synchrotron site | ESRF |
Beamline | ID14-3 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2004-07-05 |
Detector | ADSC CCD |
Spacegroup name | P 41 21 2 |
Unit cell lengths | 62.122, 62.122, 346.284 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 40.000 - 2.200 |
R-factor | 0.205 |
Rwork | 0.201 |
R-free | 0.26500 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2j3g |
RMSD bond length | 0.009 |
RMSD bond angle | 1.247 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | AMoRE |
Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 46.200 |
High resolution limit [Å] | 2.200 |
Rmerge | 0.100 |
Number of reflections | 35612 |
<I/σ(I)> | 17.6 |
Completeness [%] | 99.0 |
Redundancy | 10.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 |