2IPT

PFA1 Fab Fragment

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU
Temperature [K]113
Detector technologyIMAGE PLATE
Collection date2006-03-27
DetectorRIGAKU RAXIS IV
Wavelength(s)1.54
Spacegroup nameP 1
Unit cell lengths41.985, 42.825, 58.381
Unit cell angles95.84, 94.77, 91.91
Refinement procedure
Resolution25.190 - 2.000
R-factor0.18
Rwork0.177
R-free0.22300
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2iq9
RMSD bond length0.011
RMSD bond angle1.429
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareMOLREP
Refinement softwareREFMAC
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]25.1902.070
High resolution limit [Å]2.0002.000
Number of reflections25317
Completeness [%]93.185.1
Redundancy1.91.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION7.52940.1 M Hepes, 25% PEG3350, pH 7.5, VAPOR DIFFUSION, temperature 294K

223166