2I3W
Measurement of conformational changes accompanying desensitization in an ionotropic glutamate receptor: Structure of S729C mutant
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NSLS BEAMLINE X4A |
Synchrotron site | NSLS |
Beamline | X4A |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2004-06-24 |
Detector | ADSC QUANTUM 210 |
Wavelength(s) | 1 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 47.002, 93.142, 138.244 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 20.000 - 2.300 |
R-factor | 0.24 |
Rwork | 0.240 |
R-free | 0.28400 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1ftj |
RMSD bond length | 0.007 |
RMSD bond angle | 1.300 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | AMoRE |
Refinement software | CNS (1.1) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 20.000 | 2.400 |
High resolution limit [Å] | 2.300 | 2.300 |
Rmerge | 0.061 | 0.303 |
Number of reflections | 34777 | |
<I/σ(I)> | 25.6 | 3 |
Completeness [%] | 92.0 | 91 |
Redundancy | 5.2 | 3.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 5.5 | 277 | 0.1 M CITRATE 20% PEG 3000, pH 5.5, VAPOR DIFFUSION, HANGING DROP, temperature 277K |