2I3W

Measurement of conformational changes accompanying desensitization in an ionotropic glutamate receptor: Structure of S729C mutant

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSLS BEAMLINE X4A
Synchrotron siteNSLS
BeamlineX4A
Temperature [K]100
Detector technologyCCD
Collection date2004-06-24
DetectorADSC QUANTUM 210
Wavelength(s)1
Spacegroup nameP 21 21 21
Unit cell lengths47.002, 93.142, 138.244
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution20.000 - 2.300
R-factor0.24
Rwork0.240
R-free0.28400
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1ftj
RMSD bond length0.007
RMSD bond angle1.300
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareAMoRE
Refinement softwareCNS (1.1)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]20.0002.400
High resolution limit [Å]2.3002.300
Rmerge0.0610.303
Number of reflections34777
<I/σ(I)>25.63
Completeness [%]92.091
Redundancy5.23.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP5.52770.1 M CITRATE 20% PEG 3000, pH 5.5, VAPOR DIFFUSION, HANGING DROP, temperature 277K

222036