2HVM

HEVAMINE A AT 1.8 ANGSTROM RESOLUTION

Replaces:  1HVM
Experimental procedure
Source typeSYNCHROTRON
Source detailsEMBL/DESY, HAMBURG BEAMLINE X11
Synchrotron siteEMBL/DESY, Hamburg
BeamlineX11
Temperature [K]279
Detector technologyIMAGE PLATE
Collection date1993-07
DetectorMARRESEARCH
Spacegroup nameP 21 21 21
Unit cell lengths52.300, 57.720, 82.050
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution8.000 - 1.800
R-factor0.149
Rwork0.149
R-free0.19600

*

RMSD bond length0.010
RMSD bond angle22.900

*

Data reduction softwareMOSFLM
Refinement softwareTNT
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]9999.000

*

High resolution limit [Å]1.800

*

1.800

*

Rmerge0.048

*

0.149

*

Total number of observations107989

*

Number of reflections23188
Completeness [%]96.880.8

*

Redundancy5.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1Vapor diffusion, hanging drop

*

7Rozeboom, H.J., (1990) J.Mol.Biol., 212, 441.

*

Crystallization Reagents in Literatures
IDcrystal IDsolutionreagent nameconcentration (unit)details
11dropammonium sulfate35-65 (%sat)
21reservoirsodium chloride1.7-3.4 (M)precipitant

218853