Experimental procedure
Source type | SYNCHROTRON |
Source details | EMBL/DESY, HAMBURG BEAMLINE X11 |
Synchrotron site | EMBL/DESY, HAMBURG |
Beamline | X11 |
Temperature [K] | 279 |
Detector technology | IMAGE PLATE |
Collection date | 1993-07 |
Detector | MARRESEARCH |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 52.300, 57.720, 82.050 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 8.000 - 1.800 |
R-factor | 0.149 |
Rwork | 0.149 |
R-free | 0.19600 * |
RMSD bond length | 0.010 |
RMSD bond angle | 22.900 * |
Data reduction software | MOSFLM |
Refinement software | TNT |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 9999.000 * | |
High resolution limit [Å] | 1.800 * | 1.800 * |
Rmerge | 0.048 * | 0.149 * |
Total number of observations | 107989 * | |
Number of reflections | 23188 | |
Completeness [%] | 96.8 | 80.8 * |
Redundancy | 5.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | Vapor diffusion, hanging drop * | 7 | Rozeboom, H.J., (1990) J.Mol.Biol., 212, 441. * |
Crystallization Reagents in Literatures
ID | crystal ID | solution | reagent name | concentration (unit) | details |
1 | 1 | drop | ammonium sulfate | 35-65 (%sat) | |
2 | 1 | reservoir | sodium chloride | 1.7-3.4 (M) | precipitant |