Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

2HOY

Inter-subunit signaling in GSAM

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsEMBL/DESY, HAMBURG BEAMLINE BW7B
Synchrotron siteEMBL/DESY, HAMBURG
BeamlineBW7B
Temperature [K]100
Detector technologyIMAGE PLATE
DetectorMAR scanner 300 mm plate
Wavelength(s)0.909
Spacegroup nameP 21 21 21
Unit cell lengths65.990, 107.084, 122.053
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution19.400 - 2.200
R-factor0.22
Rwork0.220
R-free0.24800
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.006
RMSD bond angle1.300
Data reduction softwareMOSFLM
Data scaling softwareCCP4 ((SCALA))
Phasing softwareAMoRE
Refinement softwareCNS (1.1)
Data quality characteristics
 Overall
Low resolution limit [Å]19.400
High resolution limit [Å]2.200
Number of reflections41791
Completeness [%]94.7
Redundancy2.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION7.2292pH 7.2, VAPOR DIFFUSION, temperature 292K

218853

PDB entries from 2024-04-24

PDB statisticsPDBj update infoContact PDBjnumon