Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

2HII

heterotrimeric PCNA sliding clamp

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 12.3.1
Synchrotron siteALS
Beamline12.3.1
Temperature [K]100
Detector technologyCCD
Collection date2005-12-15
DetectorADSC QUANTUM 315
Spacegroup nameP 1
Unit cell lengths36.519, 87.179, 135.874
Unit cell angles89.80, 86.36, 78.33
Refinement procedure
Resolution20.000 - 2.790
R-factor0.218
Rwork0.215
R-free0.28200
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.010
RMSD bond angle1.389
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwarePHASER
Refinement softwareREFMAC
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.900
High resolution limit [Å]2.7902.790
Rmerge0.0770.238
Number of reflections37657
<I/σ(I)>12.3
Completeness [%]93.268.4
Redundancy3.73.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
15.529818-20% PEG 3350, 150mM ammonium citrate, 100mM Bis-Tris, pH 5.5, VAPOR DIFFUSION, SITTING DROP, temperature 298K, pH 5.50

237423

PDB entries from 2025-06-11

PDB statisticsPDBj update infoContact PDBjnumon