2GTL

Lumbricus Erythrocruorin at 3.5A resolution

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 14-BM-C
Synchrotron siteAPS
Beamline14-BM-C
Temperature [K]100
Detector technologyCCD
Collection date2002-01-01
DetectorADSC QUANTUM 4
Wavelength(s)0.9
Spacegroup nameP 1
Unit cell lengths176.080, 257.960, 436.530
Unit cell angles89.69, 97.15, 90.98
Refinement procedure
Resolution100.000 - 3.500
R-factor0.288
Rwork0.288
R-free0.29700
Structure solution methodMOLECULAR REPLACEMENT
Data scaling softwareHKL-2000
Phasing softwareCNS
Refinement softwareCNS
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]100.0003.630
High resolution limit [Å]3.5003.500
Rmerge0.078
Number of reflections890862
Completeness [%]89.374.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION7.52986% (w/w) PEG 8000, 10mM CaCl2, 3% isopropanol, 60mM Hepes, pH 7.5, VAPOR DIFFUSION, temperature 298.0K