Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

2GMI

Mms2/Ubc13~Ubiquitin

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 8.2.2
Synchrotron siteALS
Beamline8.2.2
Temperature [K]100
Detector technologyCCD
Collection date2005-09-25
DetectorADSC QUANTUM 315
Wavelength(s)1.0039
Spacegroup nameP 21 21 21
Unit cell lengths53.230, 86.410, 86.620
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution50.000 - 2.500
Rwork0.237
R-free0.26800
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1jat 1ubq
RMSD bond length0.007
RMSD bond angle1.496
Data scaling softwareHKL-2000
Phasing softwareEPMR
Refinement softwareCNS
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.590
High resolution limit [Å]2.5002.500
Number of reflections14242
<I/σ(I)>443.1
Completeness [%]99.696.9
Redundancy6.84.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.227717% PEG 1000, 100 mM Na/K phosphate, pH 6.2, 25 mM NaCl, VAPOR DIFFUSION, HANGING DROP, temperature 277K

219515

PDB entries from 2024-05-08

PDB statisticsPDBj update infoContact PDBjnumon