2FU0
Plasmodium falciparum cyclophilin PFE0505w putative cyclosporin-binding domain
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU FR-E |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2006-01-24 |
| Detector | RIGAKU RAXIS IV |
| Wavelength(s) | 1.54 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 32.164, 56.301, 39.712 |
| Unit cell angles | 90.00, 107.89, 90.00 |
Refinement procedure
| Resolution | 37.800 - 1.800 |
| R-factor | 0.17437 |
| Rwork | 0.171 |
| R-free | 0.22110 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 2b71 |
| RMSD bond length | 0.012 |
| RMSD bond angle | 1.271 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER (V. 1.3.1) |
| Refinement software | REFMAC (5.2.0019) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 1.830 |
| High resolution limit [Å] | 1.800 | 1.800 |
| Rmerge | 0.047 | 0.234 |
| Number of reflections | 12434 | |
| <I/σ(I)> | 13.8 | 2.7 |
| Completeness [%] | 98.7 | 82.6 |
| Redundancy | 3.2 | 2.5 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 8.5 | 291 | 20% PEG 2000 MME 0.2 M Trimethylamine N-oxide, 0.1 M Tris pH 8.5, VAPOR DIFFUSION, SITTING DROP, temperature 291K |