Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | ENRAF-NONIUS |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2004-01-16 |
Detector | ENRAF-NONIUS |
Spacegroup name | P 61 |
Unit cell lengths | 83.454, 83.454, 106.825 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 20.000 - 2.300 |
R-factor | 0.202 |
Rwork | 0.197 |
R-free | 0.24900 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1pzn |
RMSD bond length | 0.007 |
RMSD bond angle | 1.230 |
Data reduction software | LSCALE |
Data scaling software | LSCALE |
Phasing software | AMoRE |
Refinement software | CNS (1.0) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 40.000 | 2.400 |
High resolution limit [Å] | 2.300 | 2.300 |
Rmerge | 0.046 | 0.244 |
Number of reflections | 17245 | |
<I/σ(I)> | 13.2 | |
Completeness [%] | 91.2 | 89.5 |
Redundancy | 3.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.4 | 294 | 7% PEG 3350, 50 MM HEPES BUFFER, 50 MM MGCL2, 0.6 M K AC, pH 7.40, VAPOR DIFFUSION, HANGING DROP, temperature 294K |