Experimental procedure
Experimental method | MAD |
Source type | SYNCHROTRON |
Source details | SPRING-8 BEAMLINE BL26B1 |
Synchrotron site | SPring-8 |
Beamline | BL26B1 |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2004-11-27 |
Detector | RIGAKU |
Wavelength(s) | 0.9792, 0.9795, 0.9640 |
Spacegroup name | P 64 2 2 |
Unit cell lengths | 86.523, 86.523, 106.582 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 33.590 - 2.000 |
R-factor | 0.205 |
Rwork | 0.205 |
R-free | 0.23100 |
Structure solution method | MAD |
RMSD bond length | 0.010 |
RMSD bond angle | 1.400 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | SOLVE |
Refinement software | CNS (1.1) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.070 |
High resolution limit [Å] | 2.000 | 2.000 |
Number of reflections | 16483 | |
<I/σ(I)> | 14.5 | 5.2 |
Completeness [%] | 99.6 | 100 |
Redundancy | 10.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 300 | 0.05M SODIUM CHLORIDE, 1.4M AMMONIUM SULFATE, 0.1M TRIS, pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 300K |