2CW4
Crystal structure of TTHA0137 from Thermus Thermophilus HB8
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU |
| Temperature [K] | 100 |
| Detector technology | IMAGE PLATE |
| Collection date | 2005-04-18 |
| Detector | RIGAKU RAXIS IV |
| Wavelength(s) | 1.5418 |
| Spacegroup name | H 3 |
| Unit cell lengths | 59.540, 59.540, 83.740 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 27.910 - 1.800 |
| R-factor | 0.145 |
| Rwork | 0.145 |
| R-free | 0.18200 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.006 |
| RMSD bond angle | 1.300 |
| Data reduction software | HKL-2000 |
| Data scaling software | SCALEPACK |
| Phasing software | MOLREP |
| Refinement software | CNS (1.1) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 1.860 |
| High resolution limit [Å] | 1.800 | 1.800 |
| Number of reflections | 10369 | |
| <I/σ(I)> | 30.97 | 10.7 |
| Completeness [%] | 99.3 | 93 |
| Redundancy | 6.1 | 4.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6.5 | 293 | PEG1500 BIS-TRIS, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K |